{"product_id":"victron-multiplus-ii-12-3000-120-50-120v-pmp122305120","title":"Victron MultiPlus-II 12\/3000 - 120-50 - 120V [PMP122305120]","description":"\u003ch2\u003eVictron MultiPlus-II 12\/3000\/120-50: 3,000VA = 2,400 watts continuous\u003c\/h2\u003e\u003cp\u003eA 12V inverter\/charger from Victron Energy with 120V AC output: an inverter, a battery charger (up to 120 A) and an automatic transfer switch (50 A) in one box. On shore power or a generator it charges your batteries and passes AC through to the boat; when shore power drops, it switches to the batteries.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy the VA number isn't the watts:\u003c\/strong\u003e Victron rates its inverters in VA (volt-amps). This one delivers \u003cstrong\u003e2,400W continuous at 77°F (25°C)\u003c\/strong\u003e and 5,500W peak for motor and compressor start-up. Size your loads around 2,400W, not 3,000W. \u003ca href=\"\/pages\/victron-inverter-lineup\"\u003eCompare all Victron inverters →\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eWhat it will run on a boat\u003c\/h3\u003e\u003cp\u003eAt 2,400W it handles a full-size microwave, coffee maker, power tools or a hair dryer, one big load at a time, with electronics running alongside. Add up everything you'll run at the same time and leave 20–25% headroom.\u003c\/p\u003e\u003ch3\u003eBattery draw and wiring\u003c\/h3\u003e\u003cp\u003eAt full continuous output it pulls roughly \u003cstrong\u003e215 amps from a 12V battery bank\u003c\/strong\u003e (2,400W ÷ 12V ÷ 93% efficiency). Size the battery cables, DC fuse and battery bank for that current. The manual lists Victron's recommended cable and fuse sizes for this model.\u003c\/p\u003e\u003ch3\u003eMounting it in a hot engine room?\u003c\/h3\u003e\u003cp\u003eContinuous output drops as the temperature rises: \u003cstrong\u003e2,200W at 104°F (40°C)\u003c\/strong\u003e, \u003cstrong\u003e1,700W at 149°F (65°C)\u003c\/strong\u003e. In the Keys an engine room or lazarette can easily run hotter than 104°F, so size for the hottest spot you'll mount it and give it airflow.\u003c\/p\u003e\u003ch3\u003eIdle draw at anchor\u003c\/h3\u003e\u003cp\u003eSwitched on with nothing plugged in, it uses about \u003cstrong\u003e13W, roughly 26Ah per day from a 12V bank\u003c\/strong\u003e. Turn on 9 W in AES mode or 3 W in search mode to cut that down when you're off the dock.\u003c\/p\u003e\u003ch3\u003eOn shore power\u003c\/h3\u003e\u003cp\u003eSet the AC input current limit to match your dock pedestal or generator. With \u003cstrong\u003ePowerAssist\u003c\/strong\u003e, it cuts back battery charging and adds battery power during peaks so you don't trip the shore breaker. Charging is adaptive, 4-stage (default 14.4 VDC absorption \/ 13.8 VDC float), programmable for lithium, AGM or flooded banks.\u003c\/p\u003e\u003ch3\u003eSpecifications (from Victron)\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage\u003c\/td\u003e\n\u003ctd\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC input range\u003c\/td\u003e\n\u003ctd\u003e9.5–17 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous power @ 77°F (25°C)\u003c\/td\u003e\n\u003ctd\u003e3,000 VA \/ 2,400 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous power @ 104°F (40°C)\u003c\/td\u003e\n\u003ctd\u003e2,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous power @ 149°F (65°C)\u003c\/td\u003e\n\u003ctd\u003e1,700 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak power\u003c\/td\u003e\n\u003ctd\u003e5,500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charger\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer switch\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC inputs \/ outputs\u003c\/td\u003e\n\u003ctd\u003e1 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax efficiency\u003c\/td\u003e\n\u003ctd\u003e93 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdle draw\u003c\/td\u003e\n\u003ctd\u003e13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication port\u003c\/td\u003e\n\u003ctd\u003eVE.Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-40°F to 149°F (-40 to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e41.9 lb (19 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e22.8 x 10.9 x 5.8 in (578 x 277 x 148 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 107.1-16,EN-IEC 60335-1,EN-IEC 60335-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years (Victron)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVictron part number\u003c\/td\u003e\n\u003ctd\u003ePMP122305120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC \/ EAN\u003c\/td\u003e\n\u003ctd\u003e8719076057338\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-MultiPlus-II-120V-EN-.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDatasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/SLD-MPPT-Tr--MultiPlus-II-off-grid-2019-05-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eExample system wiring diagram 1\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/SLD-Parallel-Multiplus-II-with-gen-off-grid-2019-05-21.pdf\" target=\"_blank\" rel=\"noopener\"\u003eExample system wiring diagram 2\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Victron has released a newer version of this unit (part number PMP122305121). Call us if you want the current model.\u003c\/p\u003e\u003ch3\u003eBuying from OnBoard\u003c\/h3\u003e\u003cp\u003eWe install Victron systems on boats in Marathon and the Florida Keys. Not sure which size you need? Call \u003ca href=\"tel:+13059984300\"\u003e305-998-4300\u003c\/a\u003e or email \u003ca href=\"mailto:contact@sammarteli.shop\"\u003econtact@sammarteli.shop\u003c\/a\u003e and we'll help you size it and plan the wiring before you buy. Local pickup is available at \u003ca href=\"\/pages\/location\"\u003eour shop on US-1 in Marathon\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003csmall\u003eWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"https:\/\/www.P65Warnings.ca.gov\" target=\"_blank\" rel=\"noopener\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/small\u003e\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":47132137423023,"sku":"PMP122305120-VIC","price":902.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1680\/8011\/files\/96588XL.jpg?v=1782947391","url":"https:\/\/sammarteli.shop\/products\/victron-multiplus-ii-12-3000-120-50-120v-pmp122305120","provider":"OnBoard Rigging","version":"1.0","type":"link"}